C-Series 60 Amp 12/24V Regulator or LVD or Load Div

$165.55

The Xantrex / Trace C60 is a fully solid state, microprocessor-driven controller that is UL and cUL listed. C Series controllers may be configured for PV battery charging, or DC load control or DC diversion operation. Whatever the charging source, a C Series controller is sure to meet your DC controller needs.

A Controller for Virtually any DC Charging Source.

Shown with optional CM LCD Digital Display must be ordered separately(see below)

Standard Features

Silent Microprocessor Control-All C Series controllers have a powerful microprocessor at their core which increases system performance and maximizes battery life. They are fully solid state and operate silently.

PWM Charge Performance

C Series controllers all use Pulse Width Modulation (PWM) charging profiles which are designed to provide a full charge to your battery while, at the same time, minimize gassing which can shorten battery life.

3-Stage Battery Charging

All C Series controllers automatically initiate a 3-stage battery charging cycle. Bulk, Absorption, and Float modes are used to ensure that voltage and current settings accurately match the batteries' actual state of charge. This means fast-as-possible charging and extended battery life. An auto equalize mode can be easily switched off when the controller is used with sealed batteries. C Series controllers are factory set for solar PV battery charging operation.

Field Adjustable

There are a number of field configurable, user adjustments for C Series controllers. C35 and C60's can only be set for 12 or 24 VDC operation. The C40 may be configured for 12, 24 or 48 volt systems. Bulk and Float voltage set points are user adjustable which allows use with a wide variety of battery technologies including; flooded lead acid, gel, and absorbed glass mat. In addition, there are manually selectable settings for Nicad batteries.

DC Load Controller Mode

When used as a load controller, the C Series will automatically turn a DC load on or off at predetermined battery voltage settings. Both LVD (low voltage disconnect) and LVR (low voltage reconnect) set points are user adjustable.

DC Diversion Mode

In this mode, all power, which is not used to maintain a full charge on the batteries, is diverted to a load dump such as water or space heaters. Diversion mode is used to regulate microhydro and wind turbine systems which need a constant load.

LED Status Indicator

A simple to read, multi-color LED indicates operating status and is standard on all C Series controllers.

UL and cUL Listed

C Series controllers are listed by UL to exacting UL 1741 and cUL CSA 22.2 107.1-95 standards. C Series controllers are also CE compliant (European countries) and are designed to CTIK standards (Australia). Their current ratings are "real world" and do not have to be derated to comply with USA NEC 125% overcurrent requirements.

Electrical Specifications

Voltage Configurations: 12 and 24 VDC
Maximum PV Open Circuit Array Voltage: 55 VDC
Charging/Load Current (@ 25C): 60 amps DC
Maximum Peak Current: 85 amps
Maximum Voltage Drop through controller: 0.30 volts
Typical Operating Consumption: 15 ma
Recommended Breaker Size: 60 amps rated 1000% continuous duty
Recommended Wire Size: #6 AWG rated at 90 degrees C
Lead Acid Battery Settings: Adjustable
NiCad Battery Settings: Adjustable
Load Control Mode: Low Voltage Reconnect-Adjustable (sticker provided with unit) all models. User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a "grace" period.